Phantom PCC Software Release. Available for download at replace.me This latest PCC builds upon previous versions. This article provides a link to all the video tutorials Vision Research has made available for the Phantom Camera Control (PCC) software. Phantom Camera Control (PCC) Software. PCC is our latest General Release, released on July 26, For new Phantom users, download the linked PCC Available for download at replace.me when running the software natively in Spanish, Japanese and PCC has an all. Phantom Camera Control (PCC) is the main software application that allows users to get the most out of Phantom cameras. While many newer Phantom models have.❿
 
 

Software: PCC – Software. Pcc phantom software download

 
 

This storage enables the user to save digital images from the volatile DRAM to non-volatile flash memory. This first data block never contains digital image information.

Additionally, in the CineMag case, the magazine is scanned when connected to the camera, and the scanning stops at the first unerased block. So if the magazine reports that its full capacity is available for recording this is an indication that the previous erase command has been completed and there is no data on the CineMag. A subsequent erase will prepare the CineMag for its next use with the assurance no data from previous recordings is present.

Vision Research welcomes slow motion videos from our industrial users as well as our entertainment customers. Submission is easy. Send us an email phantom ametek. In the body of the email give us all the details about your shoot, equipment used, workflow and anything else you think we need to know. We will send you a permission to use form to complete. This form gives us permission to use your footage and tells us how to credit your work.

Slow motion videos in our Gallery are rotated on a weekly basis and randomly chosen for inclusion into the Gallery. In it you will find company information, new products announcements and launches, recently released case studies, and innovated ways our high speed digital video cameras are used around the world. Click here to visit our blog. A tiny speck of dust on your sensor or filter can lead to a big ugly spot on your images, which is a shame because it is usually avoidable. The longer the lens and smaller the aperture, the more pronounced the spots will appear on your image.

Accessing the Sensor The first step in sensor cleaning is accessing the sensor itself. If that is the case, the lens mount must first be removed. Be sure all shims stay with the mount and are re-installed at the end of the process. The OLPF will either be attached to the lens mount or a holder in front of the camera. The OLPF holder is also removable in order to access it and the sensor glass.

Do not touch the glass surface of the OLPF during the removal and re-installation process. Cleaning the sensor Rule 1: If the dust can be removed without using a solvent, you will save yourself a lot of headaches in getting rid of it! An important tool for every digital photographer is a bulb-style blower which forces recycled air to clean various optical surfaces. Another recommended option is to use a sensor brush, such as the Sensor Sweep brush link below , as it attracts dust particles to the bristles.

Be sure to follow the directions. You must clean the brush by blowing air on it and sweeping it across a vellum-like surface to charge the bristles before each sweep on the sensor glass.

You can also use the brush to clean the area around the sensor as dust can settle there and then get attracted back onto the sensor glass. Make sure to always blow the bristles free of dust using a bulb blower before storing it within its container. If there is a smudge or dust that won’t go away, try a sensor wipe or micro fiber lens cleaning cloth to gently wipe the smudge away.

Just like the brush, keep these items clean and dispose of sensor wipes after each use. If you reuse them, they will build up residue which will end up back on the sensor glass. For very stubborn smudges, you might want to wrap a dry sensor wipe around a long swab for better control. If that doesn’t work, a drop of Eclipse lens cleaning solution on the wipe will do the trick.

A sensor wipe folded into a point with a drop of Eclipse on the tip can help very concentrated spots as well. When inspecting the sensor or filter, be sure there is plenty of light pointed at the surface to see what you are doing.

Tech Tips. Lenses gather a lot of dust as well, which can also wreak havoc on your images. Always keep the rear and front elements protected with their lens caps. There are many products out there safe for cleaning lenses, Here at Vision Research we find that a micro fiber cloth with one drop of Eclipse or Pan-cro solution on the cloth works at the fastest with the best results. A Senor and Lens Care Kit can be purchased in our online store.

We offer hands-on training for Phantom cameras at our Wayne, New Jersey facility. The two-day class has both lecture and labs for the best learning experience. This class is targeted at applications where the cameras will be used for scientific and engineering applications. A schedule of classes can be found here. For customers outside of North America, who prefer local training, most of our International Sales Partners offer training courses tailored to your needs.

If your application is TV or Motion Picture production, consider training courses targeted at those applications from Abel Cine Tech , or other Phantom resellers around the world who focus on the “entertainment” market. There sure is! Visit our camera comparison page. All of our digital high speed cameras are listed on one page. A log can go a long way in determining what’s going on inside the camera and the performance of the controller.

To create a log, perform the following steps:. If the control unit does not detect the camera, re-check the settings of the control unit. It’s easy. If you are using PCC, power up your camera and connect it to your controller and launch the Application. For legacy software: Power up your camera and connect it to your controller and launch the Phantom application.

The following screen will show up. If you get any messages about updating or copying STG files at this point, just dismiss them 3 Minimize the Phantom software do not close 4 With the software and camera running, go into Windows Explorer and locate the existing STG. If you cannot locate the CD, please contact Technical Support at support visionresearch. What’s happening is the firewall is protecting the controller from the camera.

To alleviate this problem, the firewall needs to be disabled. In order to do this, you may need administrator privileges. Go to the control panel and locate Windows Firewall and double click on it. In the pop-up window verify the firewall is set to off. There are several steps in troubleshooting this problem. Here is the procedure if your camera is of the firewire variety please contact tech support: 1. In the C:Windowssystem32cmd. Click Enter.

If properly installed the camera should reply to the Ping Request. If the Phantom Control Unit fails to detect the camera: 1 Unplug the Cat-5 cable from the Network Phantom Control Unit computer, and ensure the proper cable type is being used.

Click the Properties button. For example: Controller Unit 1: Click OK to complete the setup If the above steps do not resolve the issue, please contact technical support at support visionresearch. Here is how you do it:. STG file. The cine file will provide the most of the information about the camera so we can diagnose your problem. When contacting Technical Support, you should have the following information:. The Phantom Camera sensor is made up of thousands of pixels whose sensitivity can drift due to changes in resolution, exposure, time and temperature.

A Current Session Reference calibrates all the pixels that will be used for a given set of camera parameters. It is usually good practice to perform a CSR anytime a change is made in camera settings or lighting. This ensures that the camera sensor will deliver the best possible picture available. Depending on the model of camera, either 1GB or 4GB of non-volatile memory is always present and is used only to store the camera’s operating system, sensor calibration data, and set-up parameters i.

However, these steps alone are insufficient to ensure a “secure” erase. But, this is not a “secure” erase. We plan to provide a command or utility to do a secure erase in the future. So if the magazine reports that its full capacity is available for recording this is an indication that the previous erase command has been completed. We test our cameras’ light sensitivity to an industry standard: ISO We use the SAT method which we think is the best method for determining a sensor’s sensitivity.

The SAT method does not use gain to boost sensitivity. When using gain to increase sensitivity, you also boost the noise level. A gain adjustment to boost sensitivity is available on all Phantom cameras using image processing tools, if increased noise can be tolerated.

We do not manufacturer such equipment, however, there are several manufacturer’s of underwater housings for all types of camera equipment. Prevco is a subsea engineering consultancy and manufacturer specializing in submersible pressure vessels, instrumentation housings, junction boxes, vent plugs, pressure relief valves and other accessories to meet all your underwater equipment needs for the Phantom line of digital high speed video cameras.

If you supply underwater housings or know of another supplier, please let us know so we can add to this list. We recommend you blow off the camera using forced or compressed air and a damp cloth.

Be very gentle. For cleaning sensors we recommend using a brush-based cleaning solution or forced air do not blow on the sensor or use canned air.

We offer a sensor cleaning kit in our online store. Sensor cleaning is a hot topic for digital camera users – Phantom and otherwise – and there are definite techniques on tackling it. Depending on your lighting situation, a tiny speck of dust on your sensor can lead to a big ugly spot on your images, which is a shame because it is usually avoidable.

The No. Use the Sensor Sweep brush, link below , as it attracts the particles to the bristles. Make sure to always blow the bristles free of dust before storing it within its container. Compressed air is OK as a quick solution, but always test the spray first away from the sensor to make sure none of the fluid comes out. Use short bursts and hold the can upright. A better solution would be to use a blower that recycles air to force the dust off of and from around the sensor.

If there is a smudge or dust that won’t go away, try a micro fiber lens cleaning cloth to gently wipe the smudge away. Just like the brush, keep the cloth clean, if you reuse them, they can build up residue, which will end up back on the sensor glass. For very stubborn smudges, you might want to wrap the micro fiber cloth or a piece of lens tissue around a pencil eraser or long swab for better control.

If that doesn’t work, a drop or spray of lens cleaning solution on the cloth will do the trick.. Lens tissue folded into a point with a drop of lens solution can help very concentrated spots as well. There are many products out there safe for cleaning lenses, Here at Vision Research, we find that a micro fiber cloth with one spray of Eclipse or Pan-cro solution on the cloth works at the fastest with the best results.

Each slo-mo Phantom camera comes with a fixed amount of very high-speed dynamic RAM. When the camera is in the pre-trigger mode you’ve pressed “Capture” in the user interface , the camera is continuously recording images into that memory. When it gets to the end of memory, it cycles back to the beginning and continues recording. This behavior is called “circular buffer recording”. The slow motion camera is always “live”. What you end up actually saving in memory is a function of how you’ve set up your trigger.

You can set it up such that only frames that occur after the trigger are saved, so any images already in memory are overwritten and you record an event after the trigger until memory is full. If you set the trigger to stop the recording and save all frames up to the time of the trigger, the camera will simply stop recording upon the trigger and all the frames in memory before the trigger will be saved.

Yes you can! Surf your way over to the Documents page of our Support section. Scroll down the page until you find the Discontinued Products selection. The datasheets are in model numbered order. Our new Remote Control Unit has Bluetooth r wireless remote capabilities.

Depending upon your camera model, you will need to outfit it with a Break-out-Box that has Bluetooth capability, or use a Bluetooth “dongle” directly on the remote port of the camera.

Then, a Bluetooth-enable RCU can be used to remotely control the camera. Engineering, Scientific, Industrial Applications USA only — Vision Research rents several of our Phantom high-speed video cameras for industrial, scientific and engineering applications. The cameras are available on a first-come, first-serve basis.

Our high speed rentals come complete with a controller laptop , cables, and a lens. There is a 2 day minimum on all camera rentals. Please contact rentals visionresearch. Our American offices only rent to companies with addresses within the US and Canada.

Check out our network of worldwide rental partners. The minimum rental period for most of our cameras is two days, and there is no maximum rental duration. We do discount rentals that are one month or longer. The controller is needed to setup and control the camera as well as download and save cine files.

You can choose a lens from our wide selection. We will also include a Northstar light, upon request. The first difference is the increase in memory. These enhancements are designed to make capturing, accessing, and managing your critical data much easier. To minimize noise and maximize image quality on any digital high-speed camera, it is important to control the sensor temperature.

By keeping the sensor at a fixed temperature, you will get better, more repeatable images. For many years, Vision Research has used thermo-electric TE coolers based on the Peltier effect to control sensor temperature.

The sensor die is attached to the TE cooler and by monitoring the temperature of the sensor, the camera can supply more or less power to the TE cooler to adjust the temperature. This technology is used on the v, v, v and v However, these cameras run so fast, that additional cooling technology is employed. On these cameras the sensor die is attached to the TE cooler, which in turn is bonded to a copper heat sink which has heat pipes attached.

The heat pipes carry excess heat away from the sensor area toward the sides of the camera where heat is removed using dual fans.

The heat pipe is a copper tube that is filled with a liquid under low pressure. One end of the heat pipe is bonded to the source of heat, in this case the copper heat sink. The other side is bonded to a heat sink which is fan cooled.

Liquid in the heat pipe moves toward the source of heat through capillary action. When it gets to the hot side of the pipe, it will turn to vapor and circulate back to the cool side where it gives up heat and turns back into liquid. The process then repeats. When optimized, this allows for cine downloads at speeds more than 5X faster than the standard Gb Ethernet interface.

Be sure the latest Intel drivers are installed, and the appropriate network address is assigned to it For example, IP The customer must supply the appropriate cable. A CAT6 cable is limited to 50m. In fact, there is a viewfinder port on the camera that will supply video and power to a viewfinder or monitor. There is a pin Amphenol connector on the back of the camera that is called the Capture Connector.

The connector has the following available signals:. All v, v, v and v cameras ship with a standard Capture Cable that connects to the Capture Connector and provides access to:. No, you must use the W power supply shipped with the camera.

Spares and replacement power supplies are available online from Vision Research. Instead, the camera powered up any time an appropriate DC voltage appeared on the power input to the camera.

This was done so that cameras can be powered up booted remotely by providing primary power and did not require physical access to the camera. However, there is a physical power switch on the v, v, v and v However, if there is a loss of primary power, then the Battery Backup power will be used to maintain camera operation and protect any stored data. When the switch is in the OFF position, the camera is off. When the switch is moved to the ON position, the camera will power-up immediately provided there is power connected to the Primary DC Power port OR the Battery Backup port on the camera.

This is your primary source of power for the camera. You can optionally connect a backup source of power—often a battery—to the backup battery power input. If the camera power switch is set to AUTO, and if there is a loss of power on the primary input, even momentarily, the backup power will immediately take over – providing uninterrupted power to the camera. Connecting power to the battery backup port will not turn on the camera.

There is no drain from the connected battery unless a loss of primary power causes the power input to switch to the battery backup. If primary power is restored, that again becomes the power source for the camera and the battery port reverts to a backup mode. The GPS port on the Phantom v, v, v and v can be used to provide date, time and location information from the GPS satellite network. The GPS connection supplies 5 volts at 0. Communication with the device is at baud over the NEMA standard protocol which is very common.

The GPS position is recorded in the Cine header file. Connection diagram is available. All of the Phantom Ultra High-Speed Cameras v, v, v and v are equipped standard with 10GB Ethernet and can be equipped with the unique CineMag interface, precisely for fast downloading.

A full resolution frame is 1 Mpx, so you can save about frames each second to a CineMag. Or, another way to state this is you can save about 1. Once a shot is saved to the CineMag it is safely stored and available for later retrieval. This means you immediately can use the camera for another shot. Images stored on a CineMag are available for later retrieval using the Phantom Camera Control PCC software with the CineMag mounted on either the camera or the offline docking station known as a CineStation, and may be downloaded either through the camera or the CineStation, using their 10Gb Ethernet ports.

Yes it will. You can connect through the remote port on the camera either with a “Remote” cable or Bluetooth dongle. If you connect using the remote port on the camera then you will also have to connect to one of the HD-SDI outputs of the camera to see video on the RCU. There is no danger. First, there is actually very little liquid in the heat pipe.

And, it is under very low pressure. So, while the liquid might freeze, it will not damage the heat pipe. Soon after powering the camera, the liquid will thaw. You should assume the camera will consume watts. This assumes that you are not using a viewfinder with the camera, but that it has a CineMag and full memory. We’ve been able to achieve these rates of speed without the use of such technology. Lexar x and GB cards have been tested and verified.

Additional cards will be verified and added to our compatibility list. CFast 2. We are working on a solution that supports 12V v-Lock or Gold-mount batteries. It will not recognize the camera model properly. There are only a few changes, but they are important.

This makes the camera more compatible with harsh environments and outdoor applications. Adding this shutter leads to the next difference: the shock rating with the shutter is now 30Gs which is lower than the shock spec on the older R-Series.

Without the shutter, the shock rating is Gs. The camera retains the highly rugged metal body along with CineFlash system compatibility and battery operation. This means longer record times can be achieved on the Flex.

Color processing: The Phantom Miro S supports the new Phantom PH16 protocol, which means improved white balance and color processing controls. Power and additional monitoring: The Flex features a separate viewfinder port and 2x auxiliary power ports, which the Phantom Miro S does not have. The Phantom Miro S does however have a built in battery port for use with common Sony camcorder batteries.

Please watch this short tutorial video on the correct way to install the battery. While many 3rd party software platforms will read Cine raw files directly, some may require a different format. PCC will convert those Cine files to a variety of standard video and image formats as required. We use cookies on our website. Some of them are essential for the operation of the site, while others help us to improve this site and the user experience tracking cookies.

You can decide for yourself whether you want to allow cookies or not. Please note that if you reject them, you may not be able to use all the functionalities of the site. The source code must either be included in the distribution or be available for no more than the cost of distribution plus a nominal fee, and must be freely redistributable under reasonable conditions.

For an executable file, complete source code means the source code for all modules it contains. It does not include source code for modules or files that typically accompany the major components of the operating system on which the executable file runs. Copyright c , , , The Regents of the University of California. Phantom is a totally digital high speed imaging system capable of recording thousands of high resolution frames per second.

If an ordinary photograph captures a moment in time, each high resolution Phantom image frame explores a remarkably unpredictable moment in time. The new version of the Phantom Camera Control Software application offers everything that the earlier versions included and much more. Virtually, every aspect of the program has been overhauled and improved, without sacrificing intuitive ease of use.

This Help file will reduce the learning curve, and ease the anxieties associated with learning how to use your Phantom camera and its powerful features quickly. In addition to this very comprehensive help file, which are actually a complete user manual, the Help File also has extensive context-sensitive help that you can access. Using the help file – This help is designed to be used on-screen.

It is extensively cross-linked so that you can find more relevant information to any subject from any location.

If you prefer reading printed manuals a PDF version of the entire help has also been provided to you. This may be useful as a reference, but you will probably find that the active hyperlinks, cross-references and active index make the on-screen electronic version of the help much more useful. Getting a printed help manual – You can find a formatted PDF version of the entire documentation designed for printing in the same directory the Phantom Camera Control application was installed.

As mentioned above, however, you will probably find that the on-screen version of the help is much more useful because of the hyperlinks and cross-references. The Help files can be access, and opened as a separate file, using any one of the methods below: 1. Select the appropriate Help file from the ‘Help’ button pull-down selection list.

Click ‘Help’ button in the associated application. It allows the end user to load firmware files into the selected visible camera, or in a camera which responds to a ping command, by introducing its IP address and a value for camera version. Phantom MultiCam – Help accessed in application The Phantom MultiCam application is a data sheet utility that allows for the controlling of connected Phantom cameras and their corresponding Cine files. It is a utility which allows the end-user to manage one or more cameras by viewing and editing parameters for recording or viewing Cine files to and from the cameras integrated memory.

It is mainly focused on handling acquisition and set up camera parameters with straightforward image feedback. The Phantom MultiCam can be run as an independent software application aiming to offer easy control over connected cameras and their corresponding Cine files. To ensure maximum product uptime and operator success, Vision Research offers a complete line of service programs, extended warranties and training classes to meet your specific product or operational needs.

Customer Service General inquires, technical troubleshooting or how to questions? We re here to help. Professional Repair Services Fast, accurate and competitively priced repairs for all of your product needs Extended Warranties Designed to add peace of mind and extend the factory warranty coverage that eliminates unexpected out of pocket expenses Customer Training Delivered in a Basic and Advanced format designed to get you quickly using our cameras or to explore the depths of our comprehensive feature set On-Site Predictive Support and Training is designed for customers who have 5 or more cameras.

This optional service program offers our customers the opportunity to receive a 1 day visit for refresher training, camera inspection, firmware upgrades and general maintenance View a list of AMECare documents available for download.

Visit our Vision Research customer community at for a variety of resources. Contact us for technical questions and service inquiries by entering a support ticket: Finally, feel free to call us at the numbers below. Eugen Botez Nr. The Phantom Camera Certification Training Program is a two-tiered training program that can reduce in-house training expenses and enhance your workforces productivity.

Our Phantom v-series Camera Certification Training Program helps engineers and technicians better understand Phantom cameras, as well as the use of Phantom software, accessories, and applications for high-speed imaging; that will deliver high quality technical and product education you require.

Our instructors provide an in-depth customer-focused hands-on learning experience for our Phantom products as well as the basics in photography through a combination of lectures; exercises, labs, and training solutions. Class size is limited to eight students per session to ensure that each student receives the individual attention he or she may need.

We believe this will allow them to maximize the use of our products and the effectiveness of their personnel. Vision Research reserves the right to accept or decline registrations, and to cancel the course and return all registration fees if enrollment is insufficient. No refunds will be made to participants who fail to cancel by at least five 5 working days before the course starts. Substitutions may be made at any time without penalty.

The latest training schedule can be found at: TrainingSchedule. If you are interested in attending, or have any question regarding the training, please contact your local Vision Research sales representative; or, use our Contact Us form to request more information located at: phantomhighspeed.

Broadcast and Cinematography Users If you are in need of training for television or motion picture production applications, please contact AbelCine if you are in the US or Canada, or contact your local Phantom sales representatives worldwide. Many of our users’ requests have been implemented and many aspects of the various Phantom applications have been improved, without sacrificing familiarity and intuitive ease of use.

This section outlines new features and improvements introduced in the software and various Help Files. This is a one time operation. Once it has been accepted the user will not see the dialog again.

Once selected it takes a few seconds to load, and then the camera must be chosen again from the top Camera drop-down menu. In global shutter mode, the Phantom camera can be used by industrial and scientific applications where a rolling shutter cannot be used due to possible motion artifacts and the progressive-scan behavior of each exposure.

If the ‘low light’ feature is selected while a Phantom camera is in the recording capture mode a ‘Low light is not permitted during recording anymore. The new behavior is particularly useful when working with several cameras at the same time within the application. Even with a single camera, users will notice that the software recovers from a camera being disconnected much more gracefully than in earlier versions.

PCC now maintains disconnected Phantom cameras and marks them as ‘Offline’, and displays both the Preview and Play Panels with a yellow border when cameras are disconnected. When re-connected the camera s will be ‘revived’ automatically by the software, which places them in the same position on the list, with their previous camera number.

PCC has also removed the ‘Refresh button, and changed the following nomenclatures not functionality : ‘All network cameras’ to ‘All discovered cameras’ ‘Camera Visibility’ to ‘See Cameras Option’ ‘See all available cameras’ to ‘All discovered ‘See only previous camera’ list to ‘From visible list’ Lastly, the list of ‘Visible camera’ is enforced exactly as set by the user when defined using the ‘From visible list’ option.

If cameras are absent from the list at PCC startup, they are simulated and revived when they reconnect if they are disconnected later they will go offline and be revived when reconnected. Utility – allows an end-user to load a camera change file supplied via Vision Research if required.

The Diagnostics and Utility features are typically used in conjunction with Technical Support. The effective EI value is referenced after the image processing Image Tools settings are dialed in. Directly below the Exposure Index pull-down selection list, PCC displays the combined value that takes into account other image processing settings. This is the effective Exposure Index value, which should be used for determining lighting and aperture.

Available on select cameras with firmware greater than phfw. This is referred to as ‘seamless-cine-switching’. Triggers are also stored and Cines are queued up, to ensure no important frames are missed in between Cine segments. Usually on an aircraft, the trigger is a switch closure to 28 volts, or it s left open circuit. Updated: Range Data Range Data can now be applied to partitioned memory. Updated: Continuous Recording Continuous Recording mode will remain active after camera reboot in case of power failure or accidental loss of power.

The issue of a user assigned Border Data logo not being able to display correctly with Miro C camera models with phfw. Note: The Border Data options will only be available when the ‘Save as file type’ format is an interpolated format. The topics in this section provide recommendations and instructions if: You’re upgrading to a new software version.

You’ve purchased an additional software licence for installation on another computer, You’ve purchased a Phantom Control Unit from a vendor other than Vision Research. These instructions detail the minimum system recommendations and preparation, program and Serial Tag Number. Requirements vary based on the camera models. The requirements shown are for the latest camera models manufactured by Vision Research and are subject to change without notification.

A more powerful computer will deliver faster display and playback, as well as shorter save and download times. Vision Research has preset IP address x. When multiple computers are used to control the same camera, each computer requires a unique IP address, for example, , , and so on.

Cine files captured by your Phantom camera are large. For best system performance, run the following routine maintenance tasks before installing the Phantom software. Backup all data files. Archive off-load Cine files that are rarely accessed. Disable virus protection software and close all open programs during the installation process. Recommended for Recently Serviced Cameras Are you re-installing your camera on your system after factory service, upgrade, or repair, if so, you received the latest release version of software?

Before you can use the new version of the software, you must first completely remove all earlier versions of the Phantom Camera Control Software, on all the computers used to control this camera.

Uninstall all earlier versions of Phantom software from all installed hard drives. If you’ve created a Desktop shortcut for Phantom, delete it manually. From Windows Explorer, find and delete the following files from all installed hard drives: ph From Windows Explorer, find and delete all earlier. When the camera is first connected to the controller, it will automatically download the updated ‘,stg’ file. Recommended for Software Upgrades Are you just upgrading from an earlier version of Phantom software?

If so you must first completely remove all earlier versions of the Phantom Camera Control Software. If AutoStart is enabled on your system, the setup begins automatically. If AutoStart is not enabled, go to next step.

Using Windows Explorer browse to the CD and double-click autorun. The Phantom InstallShield will automatically start and guide you through the software installation process. If you are asked to add the Phantom Application to a list of firewall approved applications, do so, or you will not be able to connect to a camera. Do not open the Phantom Camera Control software until all installation procedures have been completed.

Therefore, there will be no Phantom. All of the factory settings, calibrations and all important system operating settings will be stored into both an active non-volatile memory area of the camera, and a backup non-volatile memory area. This file is known as the camera’s ‘. The Phantom installation CD, supplied with each new or newly serviced camera, includes the ‘.

Serial Tag Files use the file extension. These files are specific to each camera manufactured and store the factory settings and various lookup tables for the image sensor based on the 4-Digit Camera ID number. The information in this file is also stored duplicated in the camera’s non-volatile flash memory. Under normal camera operation, this information is read by the Phantom application each time the software is started or each time a camera is accessed over the network. When started, the application first tries to read the factory settings from the computer.

If it doesn’t find the appropriate. On the flip side, if the Phantom application is started or if the camera is accessed over the network and no. If for any reason the Phantom application cannot read the. If the proper. If the default information is written to the flash the camera will still operate but the image quality will be less than optimum.

Never use an outdated. Never mix. Vision Research keeps copies of. Vision Research recommends making a backup copy of your camera’s. We also recommend placing a copy of this file in a temporary folder somewhere on your hard drive in the event you need to restore the camera’s factory calibration settings quickly.

When the camera is first connected to the controller, it will automatically download the ‘. Click the Properties button. For example: Controller 1: ; Controller Unit 2: , etc. Click OK to complete the setup. Connect one end of the Ethernet cable to the 8- or 6-pin Ethernet connector on the camera’s rear panel.

On a Phantom v7. Connect the other end of the Ethernet cable to the RJ Ethernet interface on the control computer. Most Ethernet Hubs do not permit the use of crossover cables. Therefore, a straight-thru cable is required. However, some Ethernet Layer 2 and Layer 3 switches have the capability of automatically detecting the cable type and adjust their pin-outs internally.

Connect VDC power to the camera. You may use the AC adapter supplied with your camera, a battery pack, or other DC power supply. They indicate the camera and the controller are communicating. You may now start the Phantom software by double-clicking the Phantom icon on the Windows’ Desktop. Click the Windows Start button and select the Run command. Type: cmd, and click the OK button. Click Enter. When properly installed the camera replies to the Ping Request. Should Phantom Control Unit fail to detect the camera: 1 Unplug the Cat-5 cable from the Phantom Control Unit computer, and ensure the proper cable type is being used.

The camera will reply to the Ping Request if properly installed. Unplug the Cat-5 cable from the Phantom Control Unit computer, and ensure the proper cable type is being used.

Re-insert the proper cable. Shutdown the Phantom Control Unit computer. Remove power from the camera. Restart the Phantom Control Unit computer. Re-apply power to the camera. Ping the camera again to verify the Phantom camera replies to the Ping Request.

You will now have to: 1. Exit the Device Manager. Remove power from the Phantom camera. Restart the Phantom Control Unit computer, then 4. Unplug the network connection cable from the Phantom Control Unit computer, then re-insert it. Check the list again to verify if the Phantom camera appears.

If you are still unable to establish and verify the connection, please contact Vision Research Technical Support. They are intentionally kept brief so that you can start using your camera as quickly as possible.

This Quick Start Guide aims to provide the basic steps to get started. Prepare Your Computer Camera controlling computers: 1. Must have either the Microsoft Windows 7, Windows 8, or Windows 10 operating system installed. Firewalls must be turned off. Contact your IT Group if necessary 3.

Using the Windows Control Panel set the IP address of your computer s network card to with a subnet mask. If working with a 10Gb Ethernet connection the computer s IP address should be set to with a subnet mask. Install PCC Software 1. Cable the Camera 1. Attach the supplied Ethernet cable between the Phantom camera and the computer.

Connect the supplied Capture cable to the Phantom camera. If an external trigger is being used to trigger the camera, connect it to Trigger connector on the rear panel of the camera. Select Camera for Use 1. In the Manager Control Panel double mouse-click on the Phantom camera to be used from the Cameras group folder. Define Recording Parameters 1. Click the Live tab. Click Cine Settings and define the following parameters by either the selecting the required value from the pull-down selection list, or typing the value into the respective data entry field.

Set Resolution to the required Width x Height. Choose the required Sample Rate and Exposure Time. Post Trigger to zero 0 by: a. Moving the T Trigger Position slider to the right, or b. Enter zero 0 into the Last data entry field. Click the Capture button to start recording to the camera s internal memory circular buffer.

Trigger 1. At the end of the action, click the action Trigger button at the bottom of the Live panel, or 2. Provide a switch closure or an external trigger signal TTL pulse via the Trigger connector. Edit Cine 1. Click the Play tab. Using the following Video Control Buttons to locate the first image of the Cine to be saved. Locate the first image of the Cine to be saved. Click the Mark-In button. Locate the last image of the Cine to be saved.

Click the Mark-Out button. Review edit Cine 1. Review the edited Cine using the Video Control Buttons. Click the Save Cine Save to Computer In the Save Cine window: 1. Navigate to the folder where you want to save the Cine file. Enter a file name for the Cine file in the File name: data entry field. Cine file format. Click the down-arrow of the Save Cine Confirm Computer Save 1.

Click the Open File button. In the Open Cine window: a. Navigate to the folder containing the saved Cine file. Highlight the Cine file to be opened. Click the Open button. Using the Video Control Buttons review the saved Cine file. Confirm CineMag Save 1. Click the Manager tab. Double-click on the Cine F file under the camera used to record the Cine.

Ensure that all Firewalls are turned off 2. Change the computer’s Ethernet adapter IP settings to be compatibale with the Phantom camera network: a.

Power up the camera and attach the supplied Ethernet cable between the Phantom camera and the computer. If a video monitor or an external trigger is being used to trigger the camera, connect them to the appropriate ports on the camera body. Insert CFast Card. Here is how to do this: 1. It’s recommended to take your time to admire the program’s design and number of features available. Click on the General Tools category 4. Activate the Uninstall Programs tool 5.